LR G-T MSUC
This set of codes implements Lagrangian Relaxation to solve the coordinated Generation and Transmission Maintenance Scheduling problem. The timeframe is 1 week. It is a complex optimization model that extends a normal security-constrained unit commitment (SCUC) formulation.
Test systems:
- The test cases used here include (i) a modified IEEE RTS-96 reliability test system (73-bus) and (ii) one out of the three area system (24-bus). The reference is: “The IEEE Reliability Test System-1996. A report prepared by the Reliability Test System Task Force of the Application of Probability Methods Subcommittee” and link is here.
Citation:
If you use any of our codes for your work, please cite the following as a reference:
- Xingpeng Li, “Generation and Transmission Maintenance Scheduling using Lagrangian Relaxation in AMPL”, Mar. 2023, [Online]. Available at: https://rpglab.github.io/resources/LR-MS-UC-AMPL/